Available Equipment

AVAILABLE EQUIPMENT

The Group of Building Environmental Research, (GRBES), operates under the frame of the Section of Applied Physics, Department of Physics of the University of Athens. It carries out specific research and development programs on the field of energy and environmental quality of the built environment. It is equipped with all the necessary scientific instrumentation to carry out specific energy and environmental experimental studies. In the following the main equipment of the Group is described.

MOBILE ENERGY BUS

Portable energy and environmental bus including a weather station for measuring temperature, wind speed and direction at different heights. Sensors are mounted on telescopic mast, which extends up to 20 meters high. Data is stored in a laptop pc.

Specifications:

Temperature measurement range: -20C to +80C

Measurement accuracy: +/- 0.1C

Wind direction 360deg

Wind speed 0-150m/sec

Data logging Adam 4000 series

System Bus RS-422/485 serial Number of Channels (each) 8

A/D Converter Resolution 16-bit Max. A/D Speed (throughput) 10Hz


THERMOCAM AGEMA THERMOVISION 570

THERMOCAM AGEMA THERMOVISION 570

Thermal Measurements, object surface temperature imprint. Used for the determination of thermal losses in buildings, fire detection, etc.

 

Specifications:

Object Temperature measurement range: -20C to 500C
Measurement accuracy: +/- 2% or =+/-2C
Thermal Sensitivity <0.15C
Field of view (H * V) 24’ * 18’
Detector type Focal Plane Array (FPA), uncooled microbolometer 320*240 pixels
Spectral range 7.5 to 13 micrometers, built in atmospheric filter with cut-on at 7.5 micromrters
IR spectral filter Optional, controlled from menu
Video out VHS or S-VHS
Viewfinder Colour TFT

PC-Card: One slot for type II or type III PC-card

Image storage: Full dynamics, 14-bit digital storage.


GLOBE THERMOMETER – TP 875/HD 2307.0K

HD 2307.0K Thermometer, Pt100 sensor for input of probes equipped with SICRAM module, measuring range –200°C +650°C. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Equipped with TP875 Globe-Thermometer probe for radiant heat measurements.

Specifications:

Operating conditions
Operating temperature -5…50°C, Warehouse temperature -25…65°C,  Working relative humidity 0…90%RH without condensation, Protection degree IP67
Power
Batteries 3 1.5V type AA batteries, Autonomy 200 hours with 1800mAh alkaline batteries
Power absorbed with instrument off 20Μa, Measuring unit °C – °F
Common characteristics
Resolution 0.1°C, Temperature drift @ 20°C 0.003%/°C

Dimensions
(Length x Width x Height) 140x88x38mm, Weight 160g (complete with batteries)
Display 2x41⁄2 digits plus symbols, Visible area: 52x42mm


BABUC-m Environmental monitoring station

Measures parameters that, taken as a whole, define the quality of an environment from the thermal, sound, and luminosity. The range includes a large variety of sensors and PC programmes for processing and storing acquired data, such as that for calculating the principal thermal comfort indices (moderate environments) and thermal stress indices (hot and cold environments). BABUC is a portable instrument for quickly taking measurements and, optionally, measurements with data logging

Specifications:

  • BSU102 Psychrometer, Hot wire anemometer for measuring turbulence intensity BSV105
  • Net radiometer for measuring radiation asymmetry BSR231
  • Special wavelength bands radiometers BSR007 – BSR009

EQUIPMENT TO MEASURE THERMAL RESISTANCE AND THERMAL TRANSMITTANCE OF BUILDING ELEMENTS BY IN SITU MEASUREMENTS

EQUIPMENT TO MEASURE THERMAL RESISTANCE

This measurement system is used for analysis of thermal resistance and thermal transmittance of building elements by in-situ measurement. It can be used for measurements according to ISO 9869 and ASTM C1155 / C1046 standards. The system is equipped with two heat flux sensors as well as two pairs of matched thermocouples for differential temperature measurements.

 

Specifications

TRSYS01 specifications: Test method ISO 9869 and ASTM C1155 / C1046. Measurement locations 2.  Power requirements 110-220 V, 0.5 Watt (max). Differential temperature (ΔT) matched pairs thermocouple type KX, 584.3:1989 ΔT accuracy 0.1 degree C. Heat flux sensor type HFP01. Protection sensors and MCU IP 63 Cable length 20 m (3x) and 10 m (3x). Storage capacity > 30 days of data: 10 minute and 24 hour averages. Data analysis to be performed by the user according to ISO and ASTM standards


BLOWER DOOR EQUIPMENT

Blower door with large calibrated fan that is temporarily mounted in a house door to measure the “leakiness” of the house and to assist in finding the location of the leaks. Incorporates variable speed fan so that the pressure in the house can be adjusted, and they also has door-mounting frames so that the fan can be sealed tightly into the door jamb. In order to measure the leakiness of the house, the blower door measures both the air flow through the fan and the pressure difference between the house inside and outside.

Status: Fully operational

Year acquired by the laboratory: 2004

FEATURE SPECIFICATION COMMENTS
Fan Motor 3/4 hp @ 110 vac/60 Hz Powerful, light weight and speed controllable (240 vac/50 hz option)
Flow Calibration Orifice pressure drop Multi-tap pressure sensor in fan
Maximum flow @ 50 Pa 5450 cfm (9265 m3/h) Highest flow of any portable blower door
Minimum calibrated flow 42 cfm (71 m3/h) Only one low-flow plate with plugs is required
Pressure or depressure Calibration unchanged Turn fan body around in the door frame
Speed control location On power cord Hold in hand or hang on gauge panel
Fan housing Fiberglass (black) Metal fan blade guards on each end
Fan length 10 inches (25.4 cm) Compact for easy carrying
Fan width 24 inches (61.0 cm) Fits in narrow door widths
Fan weight 36 lbs (16.4 kg) Handle on fan for carrying
Maximum current 8.7 amps Low current draw for cooler operation
Motor speed ranges 2, switch on fan Low motor speed allows for cooler low-flow operation
Motor reverse switch on fan Reverse motor rotation for quick uncalibrated flow reversal
Shipping box Weight 42 lbs (19.1 kg) Dimensions: 24.5 x 13 x 24.5 inches (62.2 x 33.0 x 62.2 cm)

Alnor Electronic Balometer

The Alnor Electronic Balometer uses thermal anemometry to measure volumetric flow. Used for determining air flow through ducts, openings etc., in order to determine ventilation rate, air change and effectiveness of ventilating systems.

Status: Fully operational

SPECIFICATIONS
range VOLUME
VELOCITY*
TEMPERATURE
50 – 2000 cfm
20 – 6000 fpm
32 – 122o F
resolution VOLUME
VELOCITY*
TEMPERATURE
0.1 cfm under 100
1 cfm above 1010.1 fpm under 100 fpm
1 fpm above 101 fpm0.1o
accuracy SUPPLY
EXHAUST
TEMPERATURE
±(3% of reading + 7 cfm)
±(4% of reading + 7 cfm)
±(1% of reading + 1o)
display , 0.44″ high, 4 – digit, 7 – segment LCD
weight , 8.7 lbs with hood attached